digirail 5000 .pdf



Nom original: digirail 5000.pdf

Ce document au format PDF 1.4 a été généré par Microsoft® Publisher 2016, et a été envoyé sur fichier-pdf.fr le 16/04/2016 à 07:48, depuis l'adresse IP 78.251.x.x. La présente page de téléchargement du fichier a été vue 742 fois.
Taille du document: 8.1 Mo (57 pages).
Confidentialité: fichier public


Aperçu du document


DR5000 DIGICENTRAL

DR5000
DIGICENTRAL
MANUAL

FIRMWARE V1.1.1
(2016-MAR-1)

© Copyright 2005 – 2016 digikeijs, the Netherlands. All
rights reserved. No information, images or any part of
this document may be copied without the prior written
permission of Digikeijs.
www.digikeijs.com

P1

DR5000 DIGICENTRAL

GENERAL
INFORMATION

www.digikeijs.com

P2

DR5000 DIGICENTRAL

1.1 Index
1.0
1.1
1.2
1.3

General information
Index
Warranty provisions
Legal notification

2
3
4
4

2.0
2.1
2.2
2.3
2.4
2.5

Product overview
General information
Technical specifications
Hardware overview
Track voltage
Compatibility

5
6
6
7
8
9

3.0
3.1
3.2
3.3
3.4
3.5
3.6
3.61
3.7
3.8
3.81
3.9

Configuration software
Introduction
Downloading software
Software installation
Connecting the DR5000
Software overview
Restoring the factory settings
Restoring LAN & Wi-Fi settings
Updating software and firmware
Firmware recovery mode
Bootloader recovery
Firmware versions

10
11
11
12
15
16
17
17
18
19
20
21

4.0
4.1
4.2
4.3
4.4

LAN en Wi-Fi
Introduction
LAN settings
Wi-Fi settings
Error message: “Access Error : Unauthorised, …….”

22
23
24
25
26

5.0
5.1
5.2
5.3
5.4
5.5
5.6
5.7
5.8
5.9

Connecting to operating software
Introduction
Connect Koploper through USB
Connect iTrain through USB
Connect iTrain through LAN
Connect Traincontroller through USB
Connect Traincontroller through LAN
Connect RocRail through USB (coming soon)
Connect RocRail through LAN (coming soon)
Connect WinDigipet through LAN

27
28
29
30
31
33
34
35
36
37

www.digikeijs.com

7.0
7.1
7.2
7.3
7.4
7.5
7.6
7.7
7.8
7.9
8.0
8.1

Configuration options
ext88N
LocoNet B
LocoNet T
Track Output
XB+FB Bus
PB-Bus
RS-Bus
Programming track
USB 2.0
Power
Infrared control

38
39
40
41
42
43
44
45
46
47
48
49

9.0
9.1

Controlling
Control options

50
51

10.0
10.1
10.2
10.3
10.4
10.5
10.6
10.7

Connection examples
S88n feedback modules (DR4088CS)
LocoNet boosters
LocoNet feedback modules
XpressNet® and R-BUS® feedback modules
(P)Booster bus boosters
RS-Bus® feedback modules (coming soon)
Infrared control (coming soon)

52
53
54
55
56
57
58
59

Basic Manual
This manual currently contains only the basic information and is being
gradually expanded. Suggestions, improvements, additions, comment or
suggestions are always appreciated.
support@digikeijs.com

® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz

P3

DR5000 DIGICENTRAL

1.2 Warranty provisions
All our products carry a 24-month manufacturer’s warranty but please read these user instructions carefully.
Damage to the product caused by non-observance of this manual will void the warranty.
NOTE! Any warranty is void if the housings of the DR5000 and/or the power supply has been opened.

Please read the following points carefully before using the DR5000.










Any warranty is void if the housings of the DR5000 or the power supply has been opened.
The controller has to be switched off at all times when working on your track.
Never connect an external power supply or other digital system to the track connector of the DR5000 controller.
This will damage the internal electronics and void the warranty even if it happens accidentally.
Never use a “Common Ground” booster in combination with the DR5000 controller.
Only use optically insulated boosters and LocoNet accessories in combination with the DR5000 “TRACK OUTPUT” to prevent damage to the controller or
peripheral equipment. When in doubt about your peripheral equipment you can always enquire at your dealer or Digikeijs.
Always use official and approved cabling to prevent short circuits and damage.
Using another DC power supply is permitted provided the voltage is between 15 volts and a maximum of 20 volts and also has CE approval. Ask your dealer for more information.
Use the DR5000 in a dry and dust-free environment.

1.3 Legal notices
All rights, changes, typing and printing errors and delivery options are reserved.
Specifications and illustrations are non-committal and not binding. All changes to hardware, firmware and software are reserved.
We reserve the right to amend the design of the product, software and/or firmware without prior notice.

Copyright
All supplied and/or downloadable Digikeijs user instructions and written instructions are copyrighted.
Duplication is not permitted without written consent from Digikeijs
www.digikeijs.com

P4

DR5000 DIGICENTRAL

PRODUCT
OVERVIEW

www.digikeijs.com

P5

DR5000 DIGICENTRAL

2.1 General product information
The DR5000 is a universal DCC controller suitable for virtually all varieties of connections that are currently available. The controller can deal with LocoNet and
XpressNet equipment and through Wi-Fi and also with mobile handhelds. Through a LAN, Wi-Fi connection or a USB connection it can be connected to a PC
whereby you can choose the LocoNet or ExpressNet protocol. So any supporting software, such as iTrain, Koploper, Windigipet, Train controller and RocRail can
communicate with this controller. Peripheral equipment such as the Roco Multimaus, the Lenz LH01, the Daisy (wired or wireless) and other LocoNet or XpressNet compatible equipment can be connected and used simultaneously.
The maximum power of the DR5000 controller is 3 amps. If you need more power please use a booster with an H bridge connector, such as the DR5033. Older
boosters with a so-called Common ground connector (e.g. Märklin®) are not suitable and lead to short circuiting or permanent damage.
The maximum power of the DR5000 controller is 3 amps. If you need more power please use a booster with an H bridge output, such as the DR5033. Older
boosters with a so-called Common ground output (e.g. Märklin®) are not suitable and lead to short circuiting or permanent damage.

2.2 Technical specifications
Protocol
Speed levels
Decoders
Decoder addresses
Solenoids
Power
Output
Connections

Software
www.digikeijs.com

:
:
:
:
:
:
:
:

DCC
14/28/128
117 simultaneously
9999, short addresses adjustable to max. 126 steps
2048 DCC solenoids
3 amps
H-Bridge
LocoNet B®
(a maximum of 128 modules with 16 inputs / 600mA / RailCom®)
LocoNet T®
((a maximum of 128 modules with 16 inputs / 600mA / RailCom®)
XpressNet®
(maximaal 30 MultiMause / 600mA)
B-Bus® (a maximum of 4 boosters)
R-Bus® (a maximum of 10 modules with 16 inputs)
S88-N (a maximum of 16 modules with 16 inputs)
RS-Bus® (a maximum of 32 modules with 16 inputs)
Programming Track (simultaneous driving and programming possible)
Power connection (a minimum of 14 volts, a maximum of 20 volts)
USB (LocoNet® and XpressNet-USB 3.6)
LAN (100 Mbit) (Lenz-LAN 3.6 and LocoNet LBServer)
Wi-Fi (Lenz-LAN 3.6 and LocoNet-LBServer)
Infrared receiver (compatible with Uhlenbrock® and Piko®)
iTrain, RocRail, Koploper, Traincontroller, DecoderPro
Win-Digipet and other compatible with LocoNet® or XpressNet®

® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz Elektronik GmbH

P6

DR5000 DIGICENTRAL

2.3 Hardware overview
1 LAN connection (100 MBit)
2 S88-N connection
3 LocoNet® B connection (LocoNet boosters)
2

4 LocoNet® T connection (LocoNet equipment)

3

4

5

6

7

9

8

10

5 Track output
6 Feedback bus (X –Bus® & R-Bus®)

1

11

7 Booster Bus (B-Bus®)
8 RS-Bus®
9 Programming track
10 USB connection
11 Power input connection
12 Track activity
13 USB activity
14 Infrared receiver
15 XpressNet® activity

12

16 STOP button (no track voltage)
17 START button (track voltage on)

22

21

20

19

18

17

16

15

14

13

18 LocoNet® activity
19 S88-N activity
20 Wi-Fi activity
21 LAN activity
22 Router activity
www.digikeijs.com

® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz

P7

DR5000 DIGICENTRAL

2.4 Track voltage and power
Track voltage
As standard the DR5000 comes with a 19 volts switched and rectified power supply with a power of at least 3.5 amps. Using another rectified power supply is
possible provided this has a minimum voltage of 15 volts/DC and maximum voltage of 20 volts/DC.
The actual track voltage always deviates 1 to 1.5 volts downwards from the voltage that is connected to the voltage input of the DR5000.
So for the standard supplied 19 volts power supply, the final track voltage is 17.5 volts.
It is not possible to set the track voltage using the hardware or the software.

Maximum power
The maximum power that the DR5000 can deliver is 3 amps.
This power is set using the software through the configuration software.
Click on the POWER menu after which you can enter a maximum for power in
the settings screen.

www.digikeijs.com

P8

DR5000 DIGICENTRAL

2.5 Compatibility
The following table shows which products are or are not compatible with the DR5000. Should you have tested a product we would like to
hear, of course. You can pass this information via the following link: support@digikeijs.com
Tested by Digikeijs

Getest by customers

In theory compatible

Not yet tested

Not compatible

soon

www.digikeijs.com

P9

DR5000 DIGICENTRAL

CONFIGURATION
SOFTWARE

www.digikeijs.com

P 10

DR5000 DIGICENTRAL

3.1 Introduction
To communicate with the DR5000 through the configuration software or a train control program, a USB connection with the PC is required. (The following
chapters describe how it can be done through Wi-Fi or LAN). To achieve this, you need the accompanying USB cable with a mini connector, a so-called USB A to
USB mini cable.

3.2 Downloading software
Do not connect the DR5000 yet, first install the software that can be
downloaded from the DIGIKEIJS website.

www.digikeijs.com/dr5000

www.digikeijs.com

P 11

DR5000 DIGICENTRAL

3.3 Software installation
After you have successfully downloaded the software it is important to unpack the downloaded file first and save it to your hard drive.
Then start the installation by double clicking on “setup” or “setup.exe”.
Ensure that you always have administrator rights on your PC.

3

Important!
Only connect the DR5000 after the installation of the Software and
Drivers was successful.
www.digikeijs.com

P 12

DR5000 DIGICENTRAL
After a few seconds the following screen appears. Click on “Next”.

If you want to change the location where the software is installed you can do so in the following screen. If there is no need it is best to leave the settings as they
are and click “Next”.

www.digikeijs.com

P 13

DR5000 DIGICENTRAL
Below you will find an overview of the settings. Click on “install” if you agree.

Now the configuration software is installed, Windows will ask you a few times if you trust the software from Digikeijs.
Once this has been done, the last screen appears. Press “Finish” and the drivers and the configuration program will now be installed.

www.digikeijs.com

P 14

DR5000 DIGICENTRAL

3.4 Connecting the DR5000
On the desktop an icon will appear by which the configuration software can be started. Don’t do this yet.
First connect to the DR5000 with the supplied USB cable.
Windows will “detect” the new hardware and install the drivers. Wait until this process is completed and you get a message from Windows that the hardware is
properly installed.
Now connect the DR5000 to your PC with the USB cable.
Windows will now assign and reserve 3 COM ports.
(the numbering of the COM ports depends on your personal PC configuration)
In the left hand image COM7 - COM9 are used.
COM7 is the communication port used for LocoNet.
COM8 is the communication port used for XpressNet.
COM9 is the communication port used to connect the configuration software with the
DR5000 hardware. The configuration software will automatically detect the right COM
port.

After the first start your Firewall will ask or the configuration software can access your
network. Answer Yes.

www.digikeijs.com

P 15

DR5000 DIGICENTRAL

3.5 Software overview
The different options are easy to approach by clicking on the respective connection.

1 LAN settings
2 S88-N settings

2

3

4

5

6

7

8

9

10

3 LocoNet B settings
4 LocoNet T settings
5 DCC settings

1

11

6 XpressNet® R-Bus® settings
7 B-Bus® settings
8 RS Bus® settings
9 Programming settings

17

12

10 USB settings / Firmware upgrade
11 Power supply settings

16

12 Activity settings
13 Infrared settings
14 Control settings
15 Serial number
16 Closing the software

15

14

13

17 Wi-Fi settings

www.digikeijs.com

® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz

P 16

DR5000 DIGICENTRAL

3.6 Restoring the factory settings
It is possible to restore the settings of the DR5000 to the factory settings.
Through the USB menu in the configuration software you can activate the Reset whereby the settings of the DR5000 are
restored to factory settings
NOTE! Restoring the factory settings has no effect on the LAN and Wi-Fi settings.

3.61 Restoring LAN and Wi-Fi settings
From firmware version 1.0.1 it is possible to restore the settings of the built-in LAN and Wi
-Fi module through the software. You can activate this reset by opening the Wi-Fi settings
menu in the configuration software.
NOTE! This option is only available after software and firmware version 1.0.1

www.digikeijs.com

P 17

DR5000 DIGICENTRAL

3.7 Updating software and firmware
The development of the DR5000 software is continuing process. With firmware updates you can equip the controller with the latest software. The configuration
software automatically checks for new versions at start-up or when online. New firmware is built-into the configuration tool. So first you have to install the latest version of the configuration software before the firmware update becomes available.
Roadmap
1)
2)
3)
4)
5)
6)
7)

First remove your current installation of the configuration software.
Download the preferred version from our website.
Install the configuration software.
Connect the DR5000 with the USB cable.
Open the configuration software.
Go to the USB2.0 menu.
Use the ‘’UPDATE DR5000” button to activate the firmware update

IMPORTANT! Do not disconnect the DR5000 when updating the
firmware. This may cause the DR5000 to become unusable.

NOTE! Updating the DR5000 always means that the settings are
put back to the factory settings.

www.digikeijs.com

P 18

DR5000 DIGICENTRAL

3.8 Firmware recovery mode
It may happen that something goes wrong while updating the firmware.
Should this happen then it is possible through the following steps to recover the firmware
into the device.
1)
2)
3)
4)
5)
6)
7)
8)
9)

9)
10)
11)

Connect the DR5000 only to the supplied power supply.
Press the green button and hold it.
Press the red button and hold it.
Release the green button while holding on to the red button.
Press the green button again.
Both the Green and Red LEDs below the GO and STOP switch will light up simultaneously.
Connect the USB cable.
Open the DR5000 configuration software.
The Firmware update screen will automatically start.

Press "UPDATE DR5000" and then click "Yes"
The firmware is now uploaded into the DR5000.
The device is now working again.

www.digikeijs.com

P 19

DR5000 DIGICENTRAL

3.81 Bootloader recovery
If the recovery procedure as described in section 3.8 (Firmware rescue, recovery mode) does not work then there is probably something wrong with the boot
loader of the DR5000. you can restore the Bootloader from the DR5000 using the following procedure.
1)
2)
3)
4)
5)
6)

Connect the power adapter and the USB cable to the DR5000
Close by a pair of tweezers the LOAD LED short.
The LOAD LED lights
Start the DR5000 Configuration Software.
The firmware update screen opens automatically.
Press "UPDATE DR5000"

7)

Then press "Yes"

8)

The firmware is loaded again and the DR5000 is functioning again.

Through the link below you can watch a video in which the above points are carried out:

https://youtu.be/wDyOsZ0cBmw

www.digikeijs.com

P 20

DR5000 DIGICENTRAL

3.9 Firmware versions
Version
1.0.0
1.0.1
1.1.1

Date
01-02-2016
15-02-2016
01-03-2016

www.digikeijs.com

Description
Eerste release.
New ability to reset the Wi-Fi Module to the factory settings through the Wi-Fi menu.
Comprehensive update. All updates are displayed in the text file that is downloaded together with the new ConfigApp.

P 21

DR5000 DIGICENTRAL

LAN
&
Wi-Fi
www.digikeijs.com

P 22

DR5000 DIGICENTRAL

4.1 Introduction
The DR5000 controller is equipped as standard with a built-in network router, as a result of which the controller is accessible through a LAN Network or wireless network. This makes it possible to connect programs such as iTrain or RocRail with network support through your own internal network without using the
USB cable. Starting up the internal router takes about 30 seconds.
Once you connect the controller to your local network your router assigns an IP address for the DR5000.
It is not possible to connect the DR5000 to your network through the internal Wi-Fi module. This Wi-Fi connection is only intended to connect the DR5000 with
a smartphone, tablet, PC or laptop.

Internet Router

Standard Wi-Fi login
SSID: DR5000-<serialnumber>
WiFi wachtwoord: 12345678

iTrain /
Rocrail

Green:
Yellow:
Blue:

www.digikeijs.com

No function yet
Connection to your LAN network is active
Wi-Fi activity

® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz

P 23

DR5000 DIGICENTRAL

4.2 LAN settings
It is possible to adjust the LAN Settings through the configuration software.
You can reach the settings by first finding the assigned IP address in your own router.
You have to enter this IP address in the field marked ‘IP address’. Next, click on one of the five options next to it.
If you don’t know exactly what you are changing exactly, it is not advisable to change the standard settings. Incorrect changes may result in the non-operation
of the internal router.

In the option ‘Protocol’ below the settings page
you can choose the preferred network protocol
that has to be used to connect external network
applications to the DR5000.

XpressNet LAN
Choose this option to connect external applications through XpressNet LAN
LocoNet over TCP/IP LBServer
Choose this option to connect external applications through LocoNet about TCP/IP
Dr. Command
Choose this option to connect future Digikeijs
applications.
If you get the error message:
“”Access Error : Unauthorised, Access to this
document requires a User ID.””
refer to page 25 for instructions.

www.digikeijs.com

P 24

DR5000 DIGICENTRAL

4.3 Wi-Fi settings
It is possible to adjust the Wi-Fi settings through the configuration software. You reach the settings by first finding the assigned IP address in your own router.
You have to enter this IP address in the field marked ‘IP address’. Next, click on one of the five options next to it. If you don’t know exactly what you are changing exactly, it is not advisable to change the standard settings. Incorrect changes may result in the non-operation of the internal router.

Important!
It is the very important to change the standard Wi-Fi password to prevent other users connecting to your DR5000 controller.

Changing this is very easy. Click on the button “Security”. Next you will see the ‘Pass Phrase’ settings in the screen below. As standard this password is
‘12345678’. Here you can enter your own password. Then click on “Apply”. The Wi-Fi password has been changed.

If you get the error message: “”Access Error: Unauthorised, Access to this document requires a User ID.”” refer to page 25 for instructions.
www.digikeijs.com

P 25

DR5000 DIGICENTRAL

4.4 Error Message: “Access Error : Unauthorised, Access ……… ”
Depending on your Windows version and security settings you may get the error message
“”Error message: “Access Error: Unauthorised, Access to this document requires a User ID. ”
when you try to reach the LAN or Wi-Fi settings through the DR5000 Software.
This is because the log in details that the DR5000 software sends to Internet Explorer have not
been accepted.
You can resolve this issue by opening Internet Explorer (or Windows 10 Edge) once on your
computer and entering the IP address of the DR5000 in the address bar.
The following screen will appear:

Here you enter the log in details once. (standard log in: admin / password admin)
Important! Tick “Remember my references”!
From now you can open the LAN and Wi-Fi settings through the DR5000 software.
NOTE! If you change the standard log in details or the password you have to repeat the aforementioned procedure with the new log in details.
www.digikeijs.com

P 26

DR5000 DIGICENTRAL

CONNECTING
TO THE
OPERATING SOFTWARE
www.digikeijs.com

P 27

DR5000 DIGICENTRAL

5.1 Introduction
There are different options to connect the operating software to the DR5000.
Connecting through COM ports
First of all you need the right COM port numbers. This can be viewed easily by connecting the DR5000 through the USB cable on your computer on which the
Configuration software has been installed. Next, in the Configuration software click on the option USB 2.0. A screen will then appear stating the
USB properties. The example below shows what protocol has been assigned to the different COM port numbers.
Connecting through LAN
To connect through the LAN network you have to look in your own router to find what IP address the DR5000 has received.

www.digikeijs.com

P 28

DR5000 DIGICENTRAL

5.2 Connect to Koploper through USB
Start Koploper and in the General menu choose a new database. In the relevant fields enter Name of database, Digital system and Port number.
In the example below the name DR5000 has been chosen. For the digital system, LocoNet has been chosen and Port number COM7.
You can find the COM port number by following the instructions on page 20 of this manual.
Click on “Next” and after that on “End”.
To check whether the connection works you can clock on the green conductor’s paddle signal in Koploper. Koploper will now connect to the
DR5000 through LocoNet and the green LED on the DR5000 will light up.
Click on the red conductor’s paddle signal and the DR5000 burns red.

The connection is successful.

www.digikeijs.com

P 29

DR5000 DIGICENTRAL

5.3 Connecting iTrain through USB
Start iTrain and in the changes menu click on interface. In the interface field choose S LocoNet©.
Open the serial tab and choose 115200 as the baud rate and the right LocoNet COM port, as explained on page 20. In the example below we’ve used COM7.

Click OK and try to connect to the DR5000 by clicking on ‘connect’. In the bottom right in iTrain you can see whether this has succeeded and if iTrain is now
‘online’. Check whether the controller responds to the stop and start button. If so, the connection has been successful!

www.digikeijs.com

P 30

DR5000 DIGICENTRAL

5.4 Connecting iTrain through LAN
Connect the DR5000 to your local network and start the DR5000 Configuration Software. Next, click on the “100baseT LAN” settings.
Now the ‘LAN Properties’ screen will open. At the bottom of this screen choose ‘XpressNet LAN’ in protocol settings and click on the green OK button.

The DR5000 is now set to accept XpressNet LAN connections.

Continue with setting up the iTrain on the next page.

www.digikeijs.com

P 31

DR5000 DIGICENTRAL
Now start iTrain and click on the changes menu in interface. In the interface field choose N Lenz XpressNet IP/LAN.
Open the tab “Network” and enter the IP address the DR5000 has received from your router.
At Port enter port number 5550.
At Timeout enter 2000ms.
Click “OK” and try to connect to the DR5000 by clicking ‘connect’ at the top of the iTrain screen.

At the bottom right in iTrain you can see whether this
has succeeded and if iTrain is now ‘online’.

Check whether the controller responds to the stop
and start button. If so, the connection has been
successful!

www.digikeijs.com

P 32

DR5000 DIGICENTRAL

5.5 Connecting Traincontroller through USB
Start Train controller and in the menu “Railroad” choose “Setup Digital Systems”. Next, click on the button “Add” to make a new connection. In “Select Digital
System” choose ‘LocoNet’. In the next screen select the corresponding LocoNet COM port.

Now test the connection by clicking on the green or red button in Train controller. The controller will follow up the assignments from Train controller.
In the bottom right you can also see the status of the connection.

www.digikeijs.com

P 33

DR5000 DIGICENTRAL

5.6 Connecting Traincontroller through LAN
Start Train controller and in the menu choose “Railroad” for “Setup Digital Systems”. Next, click on the button “Add” to make a new connection. In “Select Digital System” choose ‘Lenz Digital Plus / LAN’. In the next screen, enter the IP address of the DR5000 controller.
Press OK.

Now test the connection by clicking on the green or red button in Train controller. The controller will follow up the assignments from Train controller.
In the bottom right you can also see the status of the connection.

www.digikeijs.com

P 34

DR5000 DIGICENTRAL

5.7 Connecting RocRail through LAN / USB Xpressnet
Coming soon

www.digikeijs.com

P 35

DR5000 DIGICENTRAL

5.8 Connecting RocRail through LAN / USB LocoNet
Coming soon

www.digikeijs.com

P 36

DR5000 DIGICENTRAL

5.9 Connect Win-Digipet through LAN
Start WinDigipet and in top left of the Menu choose "System settings".
Enter the following according to the image above:
Digital system type:
through LAN:
IP address:
TCP port 1:
Transmission pause:
Position indicator:

Lenz LAN/USB-Interface
active / yes
“enter the IP address that the DR5000 has received from your
network”
5550
10
active / yes

Now close WinDigipet by clicking on Save & Close and start again to activate the controller.

In the next step the Feedback modules have to be entered.
Click on New TM module allocation, and enter the following according to the
right image:
Digital system:

Lenz LAN/USB-Interface

Feedback modules: Module 1 to 2, if you use return modules with 16 reporting points.
So for a second module with 16 reporting points, you enter Module 1 to 4.
Now close WinDigipet by clicking on Save & Close and restart to activate the
feedback modules.

www.digikeijs.com

P 37

DR5000 DIGICENTRAL

Configuration
options

www.digikeijs.com

P 38

DR5000 DIGICENTRAL

7.1 ext88N
1)
2)
3)
4)
5)
6)
7)

The number of connected S88N feedback modules with 16 inputs
The number of connected S88N feedback modules with 8 inputs
The total number of connected feedback contacts
First reported feedback contact of the 1st connected s88 module.
The entire s88 chain can be set throughout the entire reach of 1-2048 feedback modules.
When switching on Track-Out (green button) all inputs are reported through the various busses.
Not yet implemented
A complete overview of all connected S88N contacts.

1
2
3

7
4

5
6

www.digikeijs.com

P 39

DR5000 DIGICENTRAL

7.2 LocoNet B
1)
2)
3)
4)
5)

LNCV module address reading and / or programming
LocoNet reading CVs and / or program
LocoNet Feedback monitor. The different colors show the different feedback busses.
Advanced settings
Overview of connected LocoNet Boosters.

5

1

www.digikeijs.com

2

3

4

P 40

DR5000 DIGICENTRAL

7.2 LocoNet T
1)
2)
3)
4)

LNCV module address reading and / or programming
LocoNet reading CVs and / or program
LocoNet feedback monitor. The different colors show the different feedback busses.
Advanced settings

1

3

4

2
www.digikeijs.com

P 41

DR5000 DIGICENTRAL

7.4 Track Output
1)
2)
3)
4)
5)
6)
7)

Generate RailCom® cut-outs
Polarity of the RailCom® cut-out
Activate automatic RailCom polarity cut-out
Maximum load that the output can deliver to the rails
Short circuit delay before the controller switches off
Temperature of the internal amplifier
The current power that is required from the controller in milliamperes.

1
2
3
4
5
6
7

www.digikeijs.com

® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet, RS-Bus and Railcom is a trademark registered in the name

P 42

DR5000 DIGICENTRAL

7.5 XN + FB BUS
1)
2)
3)
4)
5)
6)
7)
8)
9)
10)

Switch XpressNet® on or off.
Invert commands.
Enable Loco info broadcast (Windigipet)
Base module address for feedback messages at the Xpressnet protocol.
Switch on the detection of the connected R-Bus® feedback modules.
Time interval between reports of the rbus(r) modules.
First reported feedback contact of the 1st connected s88 module.
The entire s88 chain can be set throughout the entire reach of 1-2048 feedback modules.
When switching on Track-Out (green button) all inputs are reported through the various busses.
Complete overview of all connected R-Bus® feedback modules.
Once you connect an R-Bus® feedback module, the number of feedback points is automatically detected.
Through this Wizard you can address and configure R-Bus® feedback modules.
9

10

1
2
3
4
5
6
7
8

www.digikeijs.com

® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz

P 43

DR5000 DIGICENTRAL

7.6 PB-Bus
1)
2)
3)

Short circuit delay in milliseconds.
A number of detected B-Bus® boosters.
Booster number with short circuit.

1

2
3

www.digikeijs.com

® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz

P 44

DR5000 DIGICENTRAL

7.7 RS Bus®
The RS-Bus is not yet implemented in the software. This will be implemented in the next firmware update.

www.digikeijs.com

® R-Bus, B-Bus are trademarks which are registered in the name of Modelleisenbahn GmbH. XpressNet and RS-Bus is a trademark registered in the name of Lenz

P 45

DR5000 DIGICENTRAL

7.8 Programming Track
1)
2)
3)
4)
5)
6)
7)

Choice from Service or POM (Program on Main) programme
Address number
CV number
CV Value
Bits
Status of reading out or programming
The measured load on the programming track during reading out or programming

1
2

3
4
5
6

7

www.digikeijs.com

P 46

DR5000 DIGICENTRAL

7.9 USB 2.0
1)
2)
3)
4)
5)
6)
7)

The serial number of the connected DR5000 controller
The assigned COM ports on the DR5000 controller
The current firmware version of your DR5000
The most recently available firmware version
Update the firmware of the DR5000 to the last version
Status of the firmware update
Restoring the factory settings of the DR5000

1

2

3

5

4
6
7

www.digikeijs.com

P 47

DR5000 DIGICENTRAL

8.0 Power
The Power settings are not yet implemented in the software.
This will be implemented in the next firmware update.

www.digikeijs.com

P 48

DR5000 DIGICENTRAL

8.1 Infrared control
1)
2)

Decoder addresses linked to the preferred channel on the infrared remote control.
Point addresses linked to the preferred channel on the infrared remote control.

1

2

www.digikeijs.com

P 49

DR5000 DIGICENTRAL

Controlling

www.digikeijs.com

P 50




Télécharger le fichier (PDF)

digirail 5000.pdf (PDF, 8.1 Mo)

Télécharger
Formats alternatifs: ZIP







Documents similaires


digirail 5000
notice digikeijs dr 5000
uhlenbrock power 8 63280
vmyma32
dr5097 5099 manual multilanguage nl en de fr multi 2
uhlenbrock 63410

Sur le même sujet..